Advant Controller 31 / Issued: 03.99
9 Hardware 07 KP 90 R303
8 .1
1.5.5 Networking interface
The networking interface, a special parallel interface, al-
lows the 07 KP 90 R303 communication module to be
connected to AC31 basic units (such as 07 KR 91 R353,
07 KT 92, 07 KT 93, 07 KT 94). The housing of the com-
07 KT 94
Basic Unit
Advant Controller 31
Comm. Processor RCOM
Advant Controller 31
07 KP 90
RUN
ERR
Supp.
TxD
RxD
BLK
40-pole ribbon cable
Connection part
Note: Attachment and disconnection of units on the networking
interface may only be performed when all supply voltages
are switched off.
Fig. 9: Example: Connecting 07 KP 90 R303 with 07 KT 94
7
munication module is connected to the housing of the
AC31 basic unit by a snap-fit connection. The electrical
connection is via a 40-pole ribbon cable with socket con-
nector, soldered onto the 07 KP 90 R303 side.
Mounting the expansion housing
1. Detach the cover on basic unit 07 KT 94 from the net-
working interface.
2. Plug the socket strip of the 40-pole ribbon cable se-
cured to the 07 KP 90 R303 onto the networking con-
nector of the 07 KT 94.
3. Place both units on a level surface and slide them to-
gether so that they engage.
4. Slide in the connection part to fix the housing in posi-
tion.
Note: Mounting of the 07 KP 90 R303 to 07 KR 91 /
07 KT 92 / 07 KT 93 takes place in a similar way.