Configure the RVON-C Card
Once you have a connection to Cronus, you are now ready to configure the RVON-C card within the Cronus system.
To configure the RVON-C Card, do the following:
1. From the Navigation bar at the bottom of the AZedit application, click the RVON button.
The RVON Configuration screen appears.
2. From the RVON-C drop down list, select the slot in which the RVON-C card resides, if it is not already selected.
3. In the IP Address field, enter the IP Address you have assigned to the RVON-C card.
4. In the Network Mask field, enter the Network Mask of the network to which the RVON-C card is connected.
5. In the Default Gateway field, enter the Default Gateway Address (if applicable) of the network to which the RVON-
C card is connected.
A Default Gateway is only required if the RVON-C connections are between LANs or WANs.
Under Settings for Pass-Through Serial via Ethernet
6. In the Target IP Address field, enter the target IP Address of the device you want to connect to over Ethernet.
7. From the Serial Baud Rate drop down list, select the baud rate at which the data is transmitted.
Under Settings for Connected Devices
NOTE: You MUST configure the channel settings on each end of a connection and ensure the same codec and packet
size are selected at each end. Remember, the RVON-C card has different channels which can be configured.
8. In the RVON-C Channel drop down list, select the channel you want to use to communicate to another device across
the network.
9. In the Device IP Address: field, enter the IP Address of the device to which you want to connect.