Switches and Connections
IMPORTANT: You must remove the card from the frame in order to change any DIP switch settings on the front card,
see Figure 1 on page 7).
DIP Switches
DIP Switch 1 Closed: Configuration via AZedit is disabled
Open: (Default) Configuration via AZedit is enabled.
Description: Disables configuration changes via AZedit. AZedit will still be able to view the card
configuration and connection status. The configuration can still be changed via the serial and
Telnet connections.
DIP Switch 2 Closed: Ignore saved Master Controller configuration
Open:(Default) Normal Operation
Description Ignores the last saved Master Controller configuration.
DIP Switches 3-4 Unused - Keep in Open position.
DIP Switch 5 Closed: Resets the Telnet username and password to their default values:
User = telex
Password = password
Open: (Default) Uses current username and password
Description: Enables the user to reset the Telnet Username and Password.
DIP Switch 6 Closed: Enables a serial monitor on the backcard DB9 (J2).
Open: (Default) Enables a pass-through serial port via the backcard DB9 (J2)
Description: Selects DB9 (J2) serial configuration.
DIP Switch 7 Closed: Runs the Boot Download
Open: (Default) Runs the native flash program.
Description: Switches to the boot download flash program. This program is sent with the RVON-C card in
case the native flash program becomes corrupt.
DIP Switch 8 DEBUG ONLY!
WARNING: DIP Switch 8 should always be left in the OFF position. It is reserved for
debugging and can have unintended consequences.
FIGURE 4. RVON-C DIP Switch panel
OPEN
CLOSED