4
DIP Switches
NOTE: You must remove the card from the frame in order to change any DIP switch settings.
FIGURE 1. Default DIP switch settings on the AIO-16 card (SB01).
DIP Switch 1 Controls the initial load (or reload) of the firmware.
OFF (open) Normal operation
ON (closed) Boot into debug mode.
Description When the switch is in the on position, the AIO-16 card skips the firmware programmed in flash.
When the switch is in the off position, it runs the firmware from flash.
DIP Switches 2-7
Keep in the off position.
DIP Switch 8 Debug Only
CAUTION: DIP Switch 8 should always be left in the off position. It is reserved for debugging
and can have unintended consequences.
12345678
ON
SB01