60
Baud Rates for the XCP-ADAM-MC
NOTE: J9 and J10 are RS-232, J7 and J8 are RS-485.
In DBX systems, you can elect whether to use
J7 and J8 or J9 and J10 for your second and
third AZedit ports.
CONNECTOR DESCRIPTION BAUD RATE
J1 AZedit 9600 or 38.4K
J2 Trunking 9600 or 38.4K
J3 UIO/PAP 76.8K
J4 PAP-32 9600
J5 not used
J6 not used
J7
General Purpose/Bus
Exp
9600, 19.2K, or 38.4K
J8
General Purpose/Bus
Exp
9600, 19.2K, or 38.4K
J9 AZedit 9600, 19.2K, or 38.4K
J10 AZedit 9600, 19.2K, or 38.4K
Trunking System
68-pin Master
Controller
J-2 of
XCP-ADAM-
MC
Assignment 2W
51RS485 TX/RX-
36 2 Ground
63RS232C RX
4Not Used
41 5 RS422 TX+
39 6 RS485 TX/RX+
36 7 Ground
40 8 RS232C TX
7 9 RS422 TX-
UIO-256/PAP/LCP
68-pin Master
Controller
J-3 of
XCP-ADAM-
MC
Assignment
2W
8 1 RS485 TX/RX-
9 2 Ground
3Not Used
4Not Used
44 5 RS422 TX+
42 6 RS485 TX/RX+
97Ground
8Not Used
10 9 RS422 TX-
General Purpose
68-pin Master
Controller
J-4 of
XCP-ADAM-
MC
Assignment
2W
11 1 RS485 TX/RX-
43 2 Ground
3Not Used
4Not Used
46 5 RS422 TX+
45 6 RS485 TX/RX+
43 7 Ground
8Not Used
12 9 RS422 TX-
General Purpose / Bus Exp.
68-pin Master
Controller
J-6 of
XCP-ADAM-
MC
Assignment 2W
15 1 RS485 TX/RX-
48 2 Ground
3Not Used
4Not Used
5Not Used
49 6 RS485 TX/RX+
48 7 Ground
8Not Used
9Not Used
UIO-256/PAP/LCP
68-pin Master
Controller
J-3 of
XCP-ADAM-
MC
Assignment
2W
Komentáře k této Příručce