17. Enter the first number in the Gateway IP Address.
This activates the first octet of the Gateway IP Address and clears the rest of the address.
18. Tap the encoder knob.
This confirms the first octet in the Gateway IP Address and moves you to the second octet.
NOTE: Press PGM to skip over any octet that does not need modifications.
19. Repeat steps 19 and 20 until the entire Gateway is entered.
20. Tap the encoder knob.
21. Press and hold the encoder knob to exit the menu.
The changes are now enabled.
NOTE: You can still set the IP Address without being connected to an Ethernet LAN. Once you have
entered the IP information, you will be prompted to perform a Save Cfg. The address is saved in
the keypanel until the RVON-1 is connected to an Ethernet LAN.
Top Level Menu, Rvon Conn.
Select an RVON Connection from the Top Level Menu
The RVON Conn. menu is a list of connection offers from other intercoms. This menu allows the keypanel to dynamically
select an intercom and port to which it will connect.
To select the connection offer, do the following:
1. Using the encoder knob on the KP -812, scroll to RVON Conn.
2. Tap the encoder knob to select RVON Conn.
The currently selected connection offer appears in the CWW window. If you have not previously selected the
connection, you will see none.
3. Turn the encoder knob to scroll to the connection offer to which you want to connect.
4. Tap the encoder knob to select the connection.
The connection offer begins to flash indicating that it has been selected.
5. Press and hold the encoder knob to exit the menu.
The keypanel will now connect to the select port.