43
Switches and Connections
IMPORTANT: You must remove the card from the frame in order to change any DIP switch settings on the front card,
see Figure 47 on page 43.
DIP Switch 1 Closed: Configuration via AZedit is disabled.
Open: (Default) Configuration via AZedit is enabled
Description:
Disables the configuration changes via AZedit. AZedit will still be able to view
the card configuration and connection status. The configuration can still be
changed via the serial and Telnet connections.
DIP Switches 2-4 Unused - Keep in Open Position
DIP Switch 5
Closed: Reset the Telnet user and passwords to their default value
User: telex
Password: password
Open: (Default) Uses the current user-name and password to their default values.
Description: Enables the user to reset the Telnet User-name and Password
DIP Switch 6 Closed: Enables a serial monitor on the backcard DB9 (J2).
Open: (Default) Enables pass-through serial port via the backcard DB9 (J2)
Description: Selects DB9 (J2) serial configuration.
DIP Switch 7 Closed: Runs the Boot Download.
Open: (Default) Runs the native flash program.
Description:
Switch to the boot download flash program. This program is sent with the
RVON-C card in case the native flash program becomes corrupt.
DIP Switch 8 DEBUG ONLY!
WARNING: DIP Switch 8 should always be left in the OFF position. It is reserved
for debugging and can have intended consequences.
FIGURE 47. RVON-C DIP Switch panel