2.2 UNPACKING AND INSPECTION
As soon as possible after receipt, inspect the container(s)
and contents for physical damage that may have occurred
in shipping. If damage has occurred, immediately (within
24 hours of receipt of equipment) contact the carrier in-
volved and file a claim. Save all packing materials, and
request an immediate inspection by the carrier’s insurance
claims agent.
There should be one power cord for each keypanel and
one gooseneck microphone for each keypanel ordered
with a microphone. There should be one power cord and
one interconnect cable for each expansion panel and level
control panel.
☞
For information about returns to RTS, refer to the
front of this manual.
2.3 CHECKING THE FACTORY JUMPER AND
LEVEL SETTINGS
There are several internal jumpers and level adjustments
which can be changed to modify the keypanel operation
and audio input/output levels. These have been set to meet
the requirements of most typical situations. However, if
you wish to review these settings prior to installation, re-
fer to “Electrical Adjustments”, page
14.
2.4 DIP SWITCH SETTINGS
The DIP switches are located on the back of the keypanel.
The switch settings are summarized in Table 1 and are de-
scribed in the following paragraphs.
☞
Important: Any time you change the DIP switch
settings you must turn the power off-then-on to reset.
2.4.1 Combinations of Expansion and Level
Control Panels
Dip switches 1 and 2 select the various allowable combi-
nations of expansion panels and level control panels that
can be connected to the keypanel.
2.4.2 Winking On / Off
DIP switch 3 turns the winking feature on or of. When
winking is on, the LED in each listen key will wink when
the talk key directly beneath it is on. This provides a vis-
ual reminder of any active talk paths. For some people,
this may be distracting and the feature may be turned off.
2.4.3 Logical Keypanel Address Selection
DIP switches 4-7 set the logical keypanel address, which
uniquely identifies the keypanel in the intercom system.
Zeus Intercom Systems: The logical keypanel addresses
are the numbers 1 through 8 printed on the back panel of
the Zeus frame next to the keypanel connectors. (The
number s repeat for every group of 8 connectors.) As you
connect each keypanel to a connector, use the number
printed next to that connector to set the address. For ex-
ample, if you connect a keypanel to a connector numbered
1, refer to Table 1 and set DIP switches 4 through 7 to se-
lect address 1.
ADAM CS Intercom Systems: Use the appropriate plan-
ning worksheet in the ADAM CS Installation Manual.
(Refer to the List of Tables in the front of the manual. The
planning worksheets are listed at the bottom of the List of
Tables.)
Installation Instructions, KP96 / KP97 Series Keypanels 9
DIP
Switch
Description Settings
(X=Don’t care)
Combinations SW 1 SW 2
1, 2
Combinations of
expansion and
level control
panels
0 EKP’s, 0 or 1 LCP X Open
1 EKP, 0 to 2 LCP’s Open Close
2 EKP’s, 0 to 3 LCP’s Close Close
3 Winking On / Off Open: Winking off
Closed: Winking on
Address SW 4 SW 5 SW 6 SW 7
4-7
Logical keypanel
address select.
1 Close Open Open Open
2 Open Close Open Open
3 Close Close Open Open
4 Open Open Close Open
5 Close Open Close Open
6 Open Close Close Open
7 Close Close Close Open
8 Open Open Open Close
8 Baud rate select Open: 9600 baud
Closed: 76.8 kbaud (DO NOT USE!)
Table 1. DIP Switch Summary