2 INSTALLATION
2.1 GENERAL
Installation consists of the following general steps:
1. Unpack and inspect the equipment.
2. Check that the factory default jumper positions and
level settings are appropriate for your application and
make any required changes. (The defaults are
virtually always acceptable.)
3. Set the back panel DIP switches.
4. Mount the keypanel and any accessories in an
equipment rack or bay.
5. Connect the keypanel and any accessories.
6. Power up the equipment and check operation.
7. Program the keypanel using the intercom system
configuration software (ADAMedit or Zeus-edit).
Some aspects of keypanel setup, such as key
assignment, may also be performed from the
keypanel using the programming keypad. Refer to the
“Advanced Operation” information in the KP96 /
KP97 Operating Instructions Manual.
8. Place the keypanel in service. If the keypanel keys
have been assigned prior to placing the keypanel in
service, the station operator should only need to refer
to the “Basic Operation” information in the KP96 /
KP97 Operating Instructions Manual.
8 Installation Instructions, KP96 / KP97 Series Keypanels
DIR
PROD
RACK
PL01 IFB4
TD AD
NEWS SAT1
TEL1
TEL2
FLOR
CHYR IS01 IS02 AUD1
Clear
Off
Call
Answer
Listen
Talk
Talk
Off
(Talk)
Matrix Intercom System
BY
SERIAL No.
CAUTION
DISCONNECT POWER
BEFORE OPENING
CONTROL
110
220
Figure 2. EKP96 / EKP97 Expansion Panel Reference View
LCP-100A
®
TELEX COMMUNICATIONS, INC.
Minneapolis, MN.
®
EXP. DATA IN
EXP. DATA OUT
Figure 3. LCP-100A Level Control Panel Reference View
Zobrazit stránku 7
1 2 3 4 5 6 7 8 9 10 11 12 13 ... 21 22

Komentáře k této Příručce

Žádné komentáře