RTS TM-2000 Uživatelský manuál Strana 33

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 37
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 32
Since the PS15’s internal termination is not used in this
application, the position of the Impedance Select switch
on the back panel does not matter. On the SSA-324,
switches S101 and S102 on the back panel should be set
to the Unbal position. The System A and System B
switches on the front panel should be set to CH2. For each
Zeus channel, you can start with the default analog input /
output settings. Adjust the level going from Zeus to each
belt pack using the Level to RTS trimmer on the front of
the SSA-324. Adjust the level from the belt pack to Zeus
with the Level from RTS trimmer. In this application, you
will probably leave the SSA-324 Duck trimmers in the
full clockwise position. The Null Low, Med and Hi trim-
mers can be adjusted to minimize the belt pack users own
voice in the belt pack headphones.
Getting Started, Zeus™ DSP Intercom Matrix 31
HEADSET LINESHEADSET LINES
2-Wire
In / Out
J101
Powe r
Input
TB 1 Connections
System B
S101
Sys B
BAL
Unbal
In = Bal
87654321
TB 1
Fuse
1A SB
F1
System A
1 - 4-Wire in Hi
2 - 4-Wire in Lo
3 - 4-Wire Out Hi
4 - 4-Wire Out Lo
System B
5 - 4-Wire in Hi
6 - 4-Wire in Lo
7 - 4-Wire Out Hi
8 - 4-Wire Out Lo
S102
Sys A
BAL
Unbal
2-Wire
In / Out
System A
J102 J104
TELEX COMMUNICATONS, INC. Made in the U.S.A. TW Intercom System Mode SSA324 System Interface
1 - Earth
2 - AC
3 - AC
4 - NC
PUSH PUSH
J103 I/O
MODEL PS15
POWER SUPPLY
O/N 9000678600
IMPEDANCE
SELECT
NORM
200
DUAL
400
OUTPUTS
J1, J2 CONNECT TO
TW INTERCOM SYSTEM COMPONENTS
REFER TO OPERATION MANUAL
AUDIO
COUPLING
CH1-CH2
CAUTION
FOR CONTINUED PROTECTION AGAINST FIRE,
REPLACE ONLY WITH SAME TYPE FUSE.
FUSE
0.5A SB / 120VAC
0.25A SB / 240VAC
TIP-CH1
RING-CH2
SLEEVE-COM
RTS SYSTEMS, BURBANK, CALIFORNIA MADE IN U.S.A.
PUSH
1
3
+
PUSH
1
3
+
To a Zeus Channel
To a Zeus Channel
To Another
TW5W
PS15
TW5W TW5W
BP-318BP-318
SSA-324
Figure 27. Interfacing TW Belt Packs to Zeus
The numbered callouts are the Figure numbers for cable wiring diagrams starting on page 22. On the PS15: the position of the
Impedance Select switch does not matter. On the SSA-324: set switches S101 and S102 to the Unbal position; set the front
panel System A and System B switches to CH2.
18
18
20
20
21 21
19
19
19
Zobrazit stránku 32