6 Cables and Connectors
6.1 Introduction
Each Zeus intercom system will have unique requirements
for cables, so it is not practical to supply these with Zeus.
A computer interconnect cable has been provided, but
even this may not be long enough for your system layout
requirements. Most cables will need to be custom built.
Following is some useful general information for those
who are not familiar with cable construction. Connection
diagrams are also included for all of the common types of
connections to Zeus.
6.2 Connectors
6.2.1 Types, Solder vs Solderless
Connectors for cables are of two general types: solder and
solderless. Solder connectors are the least expensive, and
the connections are repairable. However, there is more la-
bor involved when using these connectors, and some sol-
dering skill is required to make good connections.
Solderless connectors are generally much more expensive
and require special tools, which can also be expensive.
Also, the connections are not generally repairable (except
that you could probably perform solder repairs if needed).
On the other hand, cable construction is quicker with
solderless connectors. Ask your intercom dealer about
recommended sources for connectors.
6.2.2 Pin Numbers
Pin numbers are generally stamped on the connectors, but
the numbers are very small. It helps if you know that the
connectors you will be using generally follow a standard
numbering sequence, with the male and female connec-
tors having mirror-image numbering. See Figure
9.
6.3 Cable Requirements
We recommend 22AWG, stranded, twisted pair cable for
your connections. For most applications you can use un-
shielded cable. Shielded cable is only required when some
condition in the environment is inducing noise into the in-
tercom system. For keypanels and the TIF-951, the cables
should have three twisted pairs. To connect 4-wire audio
devices, you’ll need two twisted pairs. To connect single
audio inputs or outputs, such as program inputs or paging
speaker outputs, you’ll need one twisted pair. The LCP-102
and the UIO-256 require a single twisted pair. Ask your in-
tercom dealer about recommended sources for cabling.
22 Getting Started, Zeus™ DSP Intercom Matrix
9 Pin Female
1
G
3
2
D-SUB CONNECTORS
9-Pin Male
25 Pin Male
25 Pin Female
1
14
13
25
1
14
13
25
1
6
5
9
5
9
1
6
XLR CONNECTORS
1
G
3
2
3-Pin Male
3-Pin Female
6-Pin Male
6-Pin Female
5
G
3
1
6
2
4
G
5
3
1
6
2
4
Figure 9. Connector Numbering.
IMPORTANT! These are views of the connectors from
the side where you connect the wires.
3-Twisted Pairs
1-Twisted Pair
2-Twisted Pairs
3-Twisted Pairs
1-Twisted Pair
2-Twisted Pairs
UNSHIELDED CABLES
SHIELDED CABLES (OPTIONAL)
Figure 10. Cable requirements.