11
CLOSED: The RVON card holds the definitive configuration file.
OPEN (Default): The Master Controller holds the definitive configuration file.
Description: Assigns where the configuration file for the RVON products is to be stored, either on the Master
Controller or on the RVON card.
DIP Switch 3 Not Used.
Keep in Open position.
DIP Switch 4 Inhibit Reset
CLOSED: When enabled, the card is prevented from resetting after 30 seconds of no communication with
the system controller.
OPEN (Default): When disabled, the card resets after 30 seconds of no communication with the system
controller.
Description: Allows pass-through serial data to continue when the intercom is otherwise down (i.e.,
upgrades). Mainly used to keep trunking connections open when disruptions in communication on the card
occur.
DIP Switch 5 Password Reset
CLOSED: Resets the Telnet user name and password to their default values. The password is case sensitive:
User: telex
Password: password
Also, this setting disables RVONedit and resets the authentication table in RVONedit.
OPEN (Default): Uses current username and password.
Description: Enables the user to reset the Telnet username and password.
DIP Switch 6 Serial Monitor Enable
CLOSED: Enables a serial monitor on back card DB9 via Serial Port 1.
OPEN (Default): Enables pass-through serial port via the back card DB9 on both serial port 1 and serial port
2.
NOTE: Serial Port 2 is always seen as the pass-through port.
Description: Selects DB9 serial configuration.
DIP Switch 7 Boot Download Enable
CLOSED: Runs the boot download
OPEN (Default): Runs the native flash program.
Description: Switches to the boot download flash program. This program is sent with the RVON-16 card in
case the native flash program becomes corrupt.
DIP Switch 8 DEBUG ONLY!
CLOSED: Debug mode.
OPEN (Default): Normal operation mode.
WARNING: DIP Switch 8 must be left in the OPEN position. It is reserved for debugging and can have
unintended consequences.
DIP Switch 9 Serial Port Select A